電線電纜基礎知識發(fa)表時間(jian):2022-06-11 10:15 有關電(dian)(dian)線電(dian)(dian)纜基礎知識問答的(de)第(di)五部分,包(bao)括電(dian)(dian)纜清冊的(de)內(nei)(nei)容(rong)及電(dian)(dian)纜編號的(de)含(han)義,電(dian)(dian)纜目前(qian)采用(yong)的(de)敷設方法,控制二次回(hui)路接(jie)線要求,電(dian)(dian)纜排管要求,主(zhu)廠(chang)房內(nei)(nei)敷設電(dian)(dian)纜的(de)注意事項(xiang)等。 電線電纜基礎知識 60、電纜清冊的(de)內容及(ji)電纜編號的(de)含義 答:電纜(lan)清冊(ce)是施放電纜(lan)和(he)指導施工的依(yi)據(ju),運行維(wei)護的檔案資料。應列入每根(gen)(gen)電纜(lan)的編號、起始點、型號、規格、長(chang)度,并分類統(tong)計出總長(chang)度,控纜(lan)還應列出每根(gen)(gen)電纜(lan)的備用芯(xin)。 電(dian)(dian)纜編號(hao)是識別(bie)電(dian)(dian)纜的(de)標志,故要求全廠編號(hao)不重(zhong)復,并且有(you)一定的(de)含義和(he)規(gui)律,能表(biao)達電(dian)(dian)纜的(de)特(te)征。 61、電纜目前(qian)采(cai)用的敷設方法(fa)分(fen)類 答:(1)人(ren)(ren)(ren)工敷設,即采用人(ren)(ren)(ren)海戰術,在一人(ren)(ren)(ren)或(huo)多人(ren)(ren)(ren)協調指揮下,按規(gui)定進行敷設; (2)機械(xie)化敷(fu)設,即采(cai)用滾輪(lun)、牽引器、輸送(song)機,通過一同步電源進行(xing)控(kong)制,比較(jiao)安全(quan); (3)人工(gong)和機(ji)械(xie)相結合,有(you)些(xie)現場(chang)由于轉彎較(jiao)(jiao)多,施工(gong)難度大,全(quan)用(yong)機(ji)械(xie)較(jiao)(jiao)困難,所以(yi)采用(yong)此法(fa)。 62、控(kong)制二次回路接線要求 答:(1)按圖施(shi)工接線正確; (2)導線的電氣連(lian)接應牢(lao)固可靠; (3)盤柜內的(de)導(dao)線(xian)(xian)不應(ying)(ying)有接頭,導(dao)線(xian)(xian)芯線(xian)(xian)應(ying)(ying)無損傷; (4)電纜芯線端部應(ying)標明其回路編(bian)號,編(bian)號應(ying)正(zheng)確,字跡清晰且不(bu)易脫(tuo)色(se); (5)配線應整齊、清晰(xi)、美觀(guan),導線絕緣應良好、無損; (6)每(mei)個接線(xian)端子的每(mei)側接線(xian)宜為(wei)一根,最多不得超過(guo)兩(liang)根。 63、電纜排管有何要求? 答:(1)排管(guan)頂部(bu)至(zhi)地面距離,在廠房(fang)內為(wei)(wei)0.2m,人行(xing)道下為(wei)(wei)0.5m,一般地區為(wei)(wei)0.7m; (2)在變(bian)更方向及分支處(chu)均應裝置排(pai)管井(jing)(jing)坑,長(chang)度超過(guo)30mm時(shi)也應加(jia)設井(jing)(jing)坑; (3)井坑深度不(bu)小于0.8m,人孔直(zhi)徑不(bu)小于0.7mm; (4)排管應有傾(qing)向井坑0.5%~1%的排水坡度(du)。 64、對于電纜導體連(lian)接點的電阻有何要求? 答:要(yao)求連(lian)接點的(de)電(dian)阻(zu)小而且穩定(ding),連(lian)接點的(de)電(dian)阻(zu)與相同長度、相同截面的(de)導體之比值,對(dui)于(yu)(yu)新(xin)安裝的(de)終端(duan)頭(tou)和中(zhong)間頭(tou),應不大于(yu)(yu)1;對(dui)于(yu)(yu)運行(xing)中(zhong)的(de)終端(duan)頭(tou)和中(zhong)間頭(tou)這個比值不應大于(yu)(yu)1.2。 65、電纜(lan)接(jie)頭(tou)和(he)中(zhong)間(jian)頭(tou)的設計應(ying)滿足哪(na)些要求(qiu)? 答(da):應滿足的要求有(you): (1)耐壓(ya)強度高(gao),導(dao)體連接(jie)好; (2)機(ji)械(xie)強度大(da),介(jie)質(zhi)損失(shi)小(xiao); (3)結(jie)構簡單,密封性強。 66、什么(me)是電纜(lan)故障(zhang)?有幾種常見的類型? 答:電(dian)(dian)纜(lan)故(gu)(gu)障(zhang)是(shi)指電(dian)(dian)纜(lan)在預防性試驗時發(fa)生絕緣擊穿或(huo)在運行中,因絕緣擊穿、導線燒(shao)斷(duan)等而迫使電(dian)(dian)纜(lan)線路停電(dian)(dian)的(de)故(gu)(gu)障(zhang)。常見的(de)故(gu)(gu)障(zhang)有、短路故(gu)(gu)障(zhang)、斷(duan)線故(gu)(gu)障(zhang)、閃(shan)絡性故(gu)(gu)障(zhang)和混(hun)合型故(gu)(gu)障(zhang)等。 67、如何處理電(dian)纜線路的(de)單相接(jie)地故障? 答:電(dian)纜(lan)線路單相接(jie)地(di)故障一般來說,電(dian)纜(lan)導體的損(sun)傷(shang)只是(shi)局部的,如果屬于機械損(sun)傷(shang),而(er)故障點附近的土壤又較 68、在敷(fu)設前應(ying)進行哪些試驗和檢(jian)查? 答:敷設前(qian)應檢(jian)查電纜的型(xing)號(hao)、規格(ge)及(ji)長度是否(fou)符合(he)要求(qiu),是否(fou)有外(wai)力損傷(shang),低壓電纜用(yong)1000V兆歐表遙測(ce)(ce)絕(jue)緣電阻,阻值一般(ban)不低于(yu)10Mω,用(yong)2500V搖測(ce)(ce)阻值一般(ban)不抵于(yu)400Mω。 69、主廠房內敷設電纜時一般應注意什么(me)? 答(da):在主廠房內(nei)敷設電纜時一般應(ying)注意: (1)凡引至集控室的控制電纜宜架空敷設; (2)6KV電(dian)纜宜用(yong)隧道(dao)或排管敷設(she),地下水位高處亦(yi)可架空或用(yong)排管敷設(she); (3)380V電(dian)(dian)纜(lan)當(dang)(dang)兩端電(dian)(dian)纜(lan)在(zai)零米(mi)時(shi)宜(yi)用隧道、溝(gou)或排管,當(dang)(dang)一(yi)(yi)端設備在(zai)上、一(yi)(yi)端在(zai)下(xia)時(shi),可部分(fen)架(jia)空敷設,當(dang)(dang)地下(xia)水位較高時(shi),宜(yi)架(jia)空。 70、電(dian)力電(dian)纜的內屏(ping)蔽(bi)層(ceng)(ceng)與外屏(ping)蔽(bi)層(ceng)(ceng)各(ge)在什么部位(wei)?采用什么材料?有何作(zuo)用? 答:為了(le)使(shi)絕緣層和電纜(lan)導(dao)(dao)體(ti)(ti)有較好的接(jie)觸(chu),消除導(dao)(dao)體(ti)(ti)表(biao)面(mian)的不光滑引起的導(dao)(dao)體(ti)(ti)表(biao)面(mian)電場強度的增加(jia),一般在導(dao)(dao)體(ti)(ti)表(biao)面(mian)包有金屬化紙(zhi)或半導(dao)(dao)體(ti)(ti)紙(zhi)帶(dai)(dai)的內屏(ping)(ping)蔽層。為了(le)使(shi)絕緣層和金屬護套有較好的接(jie)觸(chu),一般在絕緣層外(wai)表(biao)面(mian)包有外(wai)層屏(ping)(ping)蔽層。外(wai)屏(ping)(ping)層與(yu)內屏(ping)(ping)層的材料(liao)相同,有時(shi)還外(wai)扎銅帶(dai)(dai)或編織銅絲帶(dai)(dai)。 71、簡述環氧樹(shu)脂復合物的構成及性能。 答:環氧(yang)樹(shu)脂復合物由環氧(yang)樹(shu)脂加(jia)入硬化劑(ji)、填充劑(ji)增韌劑(ji)和稀(xi)釋劑(ji)組成。具有以下性能: (1)有足(zu)夠的(de)機械強度; (2)電氣(qi)性能優良(liang); (3)電氣性能穩(wen)定; (4)與有色金(jin)屬有足夠的黏附力; (5)耐腐蝕性好; (6)戶外(wai)使用時,耐雨、耐光(guang)、耐濕熱。 72、單(dan)芯(xin)電(dian)(dian)(dian)纜護(hu)套(tao)(tao)一(yi)端(duan)接(jie)(jie)地(di)方式中(zhong)(zhong)(zhong)為什么必(bi)須安裝一(yi)條沿電(dian)(dian)(dian)纜平行敷設的(de)(de)回(hui)(hui)流(liu)線(xian)(xian)(xian)?答:在(zai)金屬護(hu)套(tao)(tao)一(yi)端(duan)接(jie)(jie)地(di)的(de)(de)電(dian)(dian)(dian)纜線(xian)(xian)(xian)路(lu)中(zhong)(zhong)(zhong),為確保護(hu)套(tao)(tao)中(zhong)(zhong)(zhong)的(de)(de)感(gan)應(ying)電(dian)(dian)(dian)壓不超過(guo)允許標準(zhun),必(bi)須安裝一(yi)條沿電(dian)(dian)(dian)纜線(xian)(xian)(xian)路(lu)平行敷設的(de)(de)導(dao)(dao)體(ti),且導(dao)(dao)體(ti)的(de)(de)兩端(duan)接(jie)(jie)地(di),這種導(dao)(dao)體(ti)稱為回(hui)(hui)流(liu)線(xian)(xian)(xian)。當發生(sheng)單(dan)相接(jie)(jie)地(di)故障時,接(jie)(jie)地(di)短(duan)路(lu)電(dian)(dian)(dian)流(liu)可(ke)(ke)以通(tong)過(guo)回(hui)(hui)流(liu)線(xian)(xian)(xian)流(liu)回(hui)(hui)系(xi)統中(zhong)(zhong)(zhong)心(xin)點,由于通(tong)過(guo)回(hui)(hui)流(liu)線(xian)(xian)(xian)的(de)(de)接(jie)(jie)地(di)電(dian)(dian)(dian)流(liu)產生(sheng)的(de)(de)磁通(tong)抵(di)消了一(yi)部分電(dian)(dian)(dian)纜導(dao)(dao)線(xian)(xian)(xian)接(jie)(jie)地(di)電(dian)(dian)(dian)流(liu)所產生(sheng)的(de)(de)磁通(tong),因(yin)而可(ke)(ke)降低短(duan)路(lu)故障時護(hu)套(tao)(tao)的(de)(de)感(gan)應(ying)電(dian)(dian)(dian)壓。 73、電纜工程可劃分為(wei)幾個項目(mu)? 答:(1)工(gong)地運輸:包(bao)括(kuo)工(gong)程材料從倉庫到(dao)施工(gong)點的裝卸、運輸和空車(che)回程。 (2)地(di)方工(gong)(gong)程:包(bao)括路面開挖、隧、溝(gou)道(dao)施工(gong)(gong)等(deng)。 (3)敷(fu)設工程:包括敷(fu)設、中間(jian)頭(tou)制作(zuo)、掀蓋板(ban)、埋(mai)管、校潮、牽引頭(tou)制作(zuo)等。 (4)兩端工程:包括支、吊橋架和其基礎的(de)制作安裝,終端頭制作,油(you)壓力(li)和信號裝置的(de)安裝,名種電氣性能測(ce)試(shi)等。 (5)塞止工程:包括充油電纜塞止頭(tou)制作,供油箱、自動排水(shui)及信號裝置的安(an)裝等。 (6)接(jie)地工程:包(bao)括絕緣接(jie)頭、換位箱(xiang)、保護器、接(jie)地箱(xiang)安裝等。 74、電纜(lan)線路的驗收應(ying)進行(xing)哪些檢查?答(da):(1)電纜(lan)規格應(ying)符合規定,排列應(ying)整齊,無損傷,標牌齊全、正(zheng)確、清(qing)晰(xi); (2)電(dian)纜的固定(ding)彎(wan)曲半徑、有關距離及單芯(xin)電(dian)力電(dian)纜的金(jin)屬護層的接線應符(fu)合要求; (3)電(dian)纜終端、中(zhong)間頭不(bu)滲漏(lou)油,安裝牢固,充油電(dian)纜油壓及表計整定值應符合要求; (4)接地良好; (5)電纜終端相(xiang)色正(zheng)確,支架等(deng)的金屬部件(jian)油漆完整; (6)電(dian)纜溝及隧道內、橋架上(shang)應(ying)無雜物,蓋板齊全。 75、電(dian)(dian)(dian)(dian)纜線(xian)(xian)路正(zheng)(zheng)序阻(zu)抗(kang)測(ce)(ce)量(liang)(liang)(liang)(liang)過程(cheng)中有(you)什么要(yao)求?答:電(dian)(dian)(dian)(dian)纜導體的(de)交流(liu)電(dian)(dian)(dian)(dian)阻(zu)和(he)電(dian)(dian)(dian)(dian)纜三(san)相(xiang)(xiang)同感抗(kang)的(de)相(xiang)(xiang)量(liang)(liang)(liang)(liang)和(he)稱(cheng)為正(zheng)(zheng)序阻(zu)抗(kang)。電(dian)(dian)(dian)(dian)纜線(xian)(xian)路的(de)正(zheng)(zheng)序阻(zu)抗(kang)一般可在電(dian)(dian)(dian)(dian)纜盤上(shang)直接(jie)測(ce)(ce)量(liang)(liang)(liang)(liang),測(ce)(ce)量(liang)(liang)(liang)(liang)時(shi)(shi)(shi)一般使(shi)用較低的(de)電(dian)(dian)(dian)(dian)壓(ya)(ya),因此,需要(yao)用降(jiang)壓(ya)(ya)進行降(jiang)壓(ya)(ya),降(jiang)壓(ya)(ya)器采用星形(xing)接(jie)線(xian)(xian),容量(liang)(liang)(liang)(liang)一般為10kVA以(yi)上(shang),有(you)較廣的(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)調節范圍,測(ce)(ce)量(liang)(liang)(liang)(liang)時(shi)(shi)(shi)交流(liu)電(dian)(dian)(dian)(dian)源(yuan)應比較穩定,以(yi)保證測(ce)(ce)量(liang)(liang)(liang)(liang)時(shi)(shi)(shi)電(dian)(dian)(dian)(dian)流(liu)達(da)到規定的(de)要(yao)求,實際的(de)讀數值必(bi)須是電(dian)(dian)(dian)(dian)纜端的(de)電(dian)(dian)(dian)(dian)壓(ya)(ya),試驗電(dian)(dian)(dian)(dian)流(liu)最(zui)好接(jie)近電(dian)(dian)(dian)(dian)纜長(chang)期(qi)允許載(zai)流(liu)量(liang)(liang)(liang)(liang),測(ce)(ce)讀各表(biao)計的(de)數值時(shi)(shi)(shi),合上(shang)電(dian)(dian)(dian)(dian)流(liu)后同時(shi)(shi)(shi)讀取三(san)個表(biao)的(de)數值。 76、根據《電業生產安全規定》,電氣工作(zuo)人員必(bi)須具備的條件是什(shen)么(me)? 答:必(bi)須具備下列條(tiao)件: (1)經醫(yi)生鑒定身體健康,無妨(fang)礙工作的病癥; (2)具(ju)備必(bi)要的電氣知識,按其職(zhi)務和工(gong)作性質掌握相(xiang)關(guan)的規(gui)程、專業技(ji)術及安全操作技(ji)術,并經考試合格(ge); (3)熟練掌握(wo)觸電(dian)急救方法。 77、電纜在運輸裝卸過(guo)程中應注意(yi)什么? 答:(1)在(zai)運輸裝卸過程中,不應使電(dian)纜及(ji)電(dian)纜盤受到損(sun)傷,嚴禁將電(dian)纜盤直接由車上推下,電(dian)纜般不應平(ping)放運輸,平(ping)放貯存。 (2)運(yun)輸或滾動電纜盤前,必須(xu)保證電纜盤牢(lao)固(gu),電纜繞緊(jin)、充油(you)電纜至壓力(li)油(you)箱(xiang)間的油(you)管應(ying)固(gu)定(ding),不得損(sun)傷(shang),壓力(li)油(you)箱(xiang)應(ying)牢(lao)固(gu),壓力(li)指示(shi)應(ying)符合要求。 78、電(dian)纜防火有(you)哪些(xie)措施(shi)? 答: (1)采用阻(zu)燃電纜; (2)采(cai)用(yong)防火電纜托架; (3)采用防火涂(tu)料(liao); (4)電纜隧道、夾層出口等(deng)處設置防火隔墻(qiang)、防火擋板(ban); (5)架空電纜應避開油(you)管道、防爆門(men),否則應有要取(qu)局部穿管或(huo)隔熱防火措施。 79、選擇(ze)電(dian)力(li)電(dian)纜的截面應從(cong)哪幾(ji)個方(fang)面考慮? 答:應考慮如下幾(ji)個方面: (1)電纜(lan)長(chang)期允許通過的工作(zuo)電流; (2)一旦短路時的熱穩定(ding)性; (3)線路上的電壓降不能超出(chu)允許工作范圍。 80、電力電纜和(he)架(jia)空(kong)線(xian)比較有哪些優點? 答:(1)運行可靠(kao),由于安裝在(zai)地下等隱蔽處(chu),受外力破壞小,發生故障的機(ji)會(hui)較少,供電安全(quan),不會(hui)給人身造(zao)成危(wei)害; (2)維(wei)護工作量小,不需頻(pin)繁的巡檢; (3)不需架設桿塔(ta); (4)有(you)助于提高功率因(yin)數。 |